Page 258 - catalgo33
P. 258

specIAl GAGInG

               outsIde And InsIde dIAMeter GAGes
               Individually designed and built for each application,
               these gages have a low-friction bushing direct-transfer
               mechanism and will repeat within one graduation.
               It is made of aluminum for light weight and to preserve the
               proper "feel". Gage contacts and rest feet are carbide for
               long wear.
          Special GaGinG  The steel tube master has carbide rests and pads for         Angled outside Diameter Gage with Setting Master
               accuracy and wear control.
               Shown here is an angled outside diameter gage in position
               on the setting master to set the indicator to zero.
               This specific gage was designed to measure the diameter
               on conical parts.



                                                                           InsIde dIAMeter GAGe
                                                                           Inside diameter gage, moderately deep reach. Design
                                                                           permits inside measuring, while clearing hub obstructions.
                                                                           (Conventional straight bar would be used otherwise).





























                                                      MultI-reAdout And specIAl purpose GAGes
                                                      This complex five-station fixture gage checks critical dimensions and geometry of
                                                      precision cylinders.
                                                      This single fixture checks overall length to ±.010", squareness and parallelism of the
                                                      ends to within .002", longitudinal bow to within .005", out-of-roundness to within .003"
                                                      T.I.R, and wall thickness to within ±.003".
                                                      The gage includes micrometer head height adjustment of the work-staging V-rests.
                                                      It has precision ball slide mounts for dial indicators at two of the stations and wear-
                                                      resisting carbide contacts at all gaging stations.


                Inserting ceramic cylinder in gage to check squareness and
                parallelism of ends, longitudinal bow and out-of-roundness





               258
   253   254   255   256   257   258   259   260   261   262   263